Uses:
The equipment is mainly used for road vehicles - Ingress Protection (IP code) - Electrical equipment against foreign objects, water and protective contact, especially for testing and evaluation of lighting, fans, wiring harness and other electrical components of the vehicle to determine whether the product performance is able to meet international standards . In order for the product design, improve, test and the use of factory inspection.
The main parameters
Model | LX-500-4K | LX-010-4K | LX-020-4K | |
Studio size mm | D | 800 | 1000 | 1300 |
W | 800 | 1000 | 1400 | |
H | 800 | 1000 | 1300 | |
outside size mm | D | 1100 | 1300 | 1700 |
W | 1300 | 1500 | 1900 | |
H | 1800 | 2000 | 2300 | |
Water hole size mm | ¢0.8 | |||
Tube radius mm | 200 | 400 | 600 | |
Water hole spacing mm | 50 | |||
Water flow | 0.6L/min | |||
Tube swings | ±60°、±180°(Approaching) | |||
Rain water pressure | 400KPa | |||
The outer box material | SUS304 stainless steel plate | |||
Within the box material | SUS304 stainless steel plate | |||
Observation window | 1, equipped with wiper | |||
Controller | Touchscreen Programmable Controllers | |||
Protector | Leakage Protection、Water protection、Water full indication | |||
Power V | 220 or 380 | |||
Total power KW | 3 | 4 | 5 | |
Meet the standards | ISO20653、DIN040050(IP4K) |